MedicalDeals Anesthesia System features configurable inspiratory to expiratory ratios from two to one up to one to six. It supports ventilation modes including Intermittent Positive Pressure Ventilation, Assist Control, Synchronized Intermittent Mandatory Ventilation, and Manual modes for flexible patient care.
Anaesthesia-System-MD-ANS-1002
Anaesthesia System MD-ANS-1002
Overview :
Anesthesia system MD-ANS-1002 offers an Inspiratory to Expiratory Ratio Configurable from 2:1 to 1:6. It provides the ability to
fine-tune the breathing cycle. It also provides precise gas flow control for O2, N2O, and AIR, ranging from 0.1 to 10 L/min each.
The system is designed for ease of operation with intuitive controls and a digital display. That provides real-time monitoring and
alarm notifications. Our Anesthesia system is ideal for modern operating rooms, offering advanced control, flexibility, and safety
features that cater to the diverse needs of patients.
Features:
10.4"Colorful TFT LCD
Adjustable ventilation rates
Rapid Oxygen Supply
SIGH: prevent atelectasis
Oscillogram Display
AC Power Failure Alarm
Internal Battery Backup
Low Voltage Alarm
Vaporizer Safety
Suffocation Warning
Power Failure or No Connection Alert
Standard accessories:
Anesthetic breathing system × 1
Power cord 4m × 1
Fuse × 2
Fuse × 1
O cell × 1
2
Breathing tube × 2
Breathing tube × 1
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Straight connector (?22 to ?22) × 1
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 1
High pressure O hose × 1
2
High-pressure AIR hose × 1
High pressure N O hose × 1
2
Optional accessories:
CO sensor × 1
2
Transfer and receiving system of exhaust gas × 1
Patient monitor × 1
Applications:
Anesthesia System MD-ANS-1002 offers high performance in ICUs, operating rooms, and anesthesiology ensuring maximum
patient safety and ease of use across adult, child, and infant anesthesia and respiratory care.
Specifications :
Ventilation Modes IPPV, A/C, SIMV, SIGH, MANUAL
Gas Source O , N O, AIR
2 2
O : 0.1 to 10 L/min;
2
Flowmeter range N O: 0.1 to 10 L/min
2
AIR: 0.1 to 10 L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume (Vt) range 0, 20 mL to 1500 mL
Minute Volume (MV) 0 L/min to 100 L/min
Maximum Minute Volume ?18 L/min
Frequency range 1 /min to 100 /min
Inspiratory Ratio (I) 2:1 - 1:6
Positive End-Expiratory Pressure (PEEP) 0 cmH O to 30 cmH O
2 2
Pressure Triggering Sensitivity (P ) -20 cmH O to 20 cmH O
Tr 2 2
Flow Trigger Sensitivity (F ) 0.5 L/min to 30 L/min
Tr
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH O to 100 cmH O
2 2
Bellow 1.5L
P-T (Pressure-Time),
Oscillogram Types F-T (Flow-Time),
P-V loop (Pressure-Volume Loop)
AC Power Failure Alarm Yes
Battery Backup Low Voltage Alarm Yes; threshold 11.3 ± 0.3 V
Tidal Volume Alarm Triggered if no tidal volume is detected
19 % to 100 % (High);
High/Low Oxygen Concentration Alarm
18 % to 99 % (Low)
High: 20 cmH O to 100 cmH O;
Airway Pressure Alarms 2 2
Low: 0 cmH O to 20 cmH O
2 2
Adult: 5 L/min to 20 L/min;
Minute Volume Alarms
Pediatric: 1 L/min to 15 L/min
Continuous Pressure Alarm Over (PEEP + 1.5 kPa) for 16 s
Suffocation Warning 5 s to 60 s with no spontaneous ventilation
Maximum Limited Pressure ?12.5 kPa
Fan Error, Oxygen Deficit, Power Failure Displayed on screen
Display 10.4"Colorful TFT LCD
Power Consumption 80VA
Voltage: 100 to 240 V
Power Supply
Power Frequency: 50/60 Hz
Packing Dimension 920 × 970 × 1390 mm
Net Weight 87.5 kg
Gross Weight 155 kg