Uploaded on Apr 10, 2025
MedicalDeals Anesthesia System offers precise respiratory control with a positive end-expiratory pressure range of 0 to 30 cmH2O. It supports IPPV, Assist Control, Synchronized Intermittent Mandatory Ventilation, Sigh, and Manual modes. Features include a 7-inch LED display and rapid oxygen delivery.
Anesthesia-System-MD-ANS-1001
Anesthesia System MD-ANS-1001
Overview :
Anesthesia System MD-ANS-1001 provides a Positive End Expiratory Pressure range of 0 to 30 cmH2O. It provides a versatile
ventilation parameter range of tidal volumes from 20 mL to 1500 mL. This advanced system offers a variety of ventilation modes
and adjustable parameters. It also provides a wide frequency range ensuring precise control and customized care to meet the needs
of each patient. Our anesthesia system is a highly efficient and adaptable solution ideal for anesthesia and critical care settings.
Features:
Oxygen sensor
Versatile Ventilation Modes
7-inch LED display
ACGO and Fast Oxygen supply
Precise Control of Respiratory Parameters
Advanced Alarm System
Comprehensive Monitoring
Oscillogram Display
Built-in backup battery
2-3 hours backup battery
Emergency and revival after operation
Compact and Durable Design
Standard accessories:
Anesthetic breathing system × 1
Power cord × 1
Fuse × 8
Fuse × 1
Fuse × 2
O cell × 1
2
CO sensor
2
Breathing tube × 2
Breathing tube × 2
Y connector Adult × 1
Y connector Child × 1
L connector × 2
Reservoir bag 1L × 1
Reservoir bag 3L × 1
Anesthetic mask adult × 1
Anesthetic mask infant × 1
Anesthesia Vaporizer × 2
High pressure O hose × 1
2
High-pressure AIR hose × 1
High pressure N O hose × 1
2
Optional accessories:
Mainstream CO Sensor × 1
2
Sidestream CO Module × 1
2
Mainstream gas Analyzers × 1
Sidestream gas Analyzers × 1
CO Mainstream Module × 1
2
CO Sidestream Module × 1
2
Multi-gas Sensor × 1
Transfer and receiving system of exhaust gas × 1
Applications:
Anesthesia System MD-ANS-1001 is ideal for patients who require ventilatory support, including those experiencing respiratory
failure, trauma, or undergoing emergency surgeries.
Specifications :
Ventilation Modes IPPV, A/C, SIMV, SIGH, MANUAL
Gas Source O , N O, AIR
2 2
O : 0.1 to 10 L/min;
2
Flowmeter range N O: 0.1 to 10 L/min
2
AIR: 0.1 to 10L/min
Rapid Oxygen Supply Range 25 L/min to 75 L/min
Oxygen Concentration 15 % to 100 %
Tidal Volume (Vt) range 0, 20 mL to 1500 mL
Frequency range 1 /min to 100 /min
Inspiratory Ratio (I.E) 2:1 - 1:6
Minute Volume (MV) 0 L/min to 100 L/min
Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O
Pressure Triggering Sensitivity (P ) -20 cmH O to 20 cmH O (Based on PEEP)
Tr 2 2
Flow Trigger Sensitivity (F ) 0.5 L/min to 30 L/min
Tr
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5 s to 60 s
Gas Pressure Range 280 kPa to 600 kPa
Pressure Limit 20 cmH O to 100 cmH O
2 2
Bellow 1.5L
P-T (Pressure-Time),
Oscillogram Types F-T (Flow-Time),
P-V loop (Pressure-Volume Loop)
The AC power failure alarm Power failure or no connection
Alarm for backup battery 11.3 ± 0.3 V
No tidal volume ? 5 mL within 6 s
High oxygen concentration alarm 19% to 100%
Low oxygen concentration alarm 18% to 99%
High airway pressure alarm 20 cmH O to 100 cmH O
2 2
Low airway pressure alarm 0 cmH O to 20 cmH O
2 2
High-minute volume alarm Adult (5 L/min - 20 L/min)
Low-minute volume alarm Paed (1 L/min - 15 L/min, 0 - 10 L/min)
Continuous pressure alarm (PEEP+1.5 kPa) over 16s
Suffocation warning 5 s – 60 s no spontaneous ventilation
The maximum limited pressure 12.5 kPa
Fan error Shows on screen
Oxygen deficit Shows on screen
Display 7-inch LED screen
Power Consumption 40 VA
Power Supply Voltage: 100 to 240 V Power Frequency: 50/60 Hz
Packing Dimension 760 × 970 × 1550 mm
Net Weight 82.5 kg
Gross Weight 143 kg
156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN, Uk
Email: [email protected] | Website: www.medicaldeals.com | Phone: +1 506 699 0674