Uploaded on Apr 16, 2025
Medical Deals Blood and Infusion Warmer offers an adjustable temperature range from thirty-five to forty-two degrees Celsius with a high accuracy of plus or minus one degree. It ensures effectiveness and safety with hardware and software control, ideal for surgeries, trauma, and critical
Blood-and-Infusion-Warmer-MD-BIW-1000
Blood and Infusion Warmer MD-BIW-1000
Overview:
Blooda n d I n f u s i o n W a r m e r M D - B I W -
1 0 0 0 f e a t u r e s a n a d j u s t a b l e t e m p e r a t u r e r a n g e f r o m 3 5 . 0 t o 4 2 . 0 ° C w i t h a n a c c u r a c y of
±1°C. Designed for use in surgeries, trauma care, and situations with significant blood loss. It offers overheat protection at 46°C.It
can be used with standard single-use PVC blood or IV tubes with a diameter of 3.4 to 4.5 mm. This device helps prevent
hypothermia by rapidly bringing fluids to a safe, body-like temperature. Our Blood and infusion warmer ensures safety, accuracy,
and flexibility across diverse healthcare settings.
Features:
Adjustable Temperaturerange
Hardware and software temperature controlprotection
Effective and safeheating
FastHeating
Durableconstruction
3 Heating grooves to meet differentneeds
HighAccuracy
Small and compactdesign
L i g h t w e i g h t a n d P o r t a b l e
Applications:
OurBloodandInfusionWarmerMD-BIW-
1000isusedintheICU,NICU,Paediatr icDepartment,EmergencyDepartment,and Outpatient Department for
heating blood or infusion during surgery, trauma care, or in cases of severe blood loss.
Specifications:
35.0 to 42.0?
TemperatureSetting
95.0 to 107.6?
?: ?±1?
Temperature Accuracy andDeviation
?: ?±1.8?
0.1?
TemperatureIncrement
0.2?
OptionalUnit ? /?
Warming UpTime ?2min
OverheatProtection 46 ?, hardware and softwareprotection
Blood and IntravenousSets Standard single-used PVC blood or IV tubes (diameter: 3.4 to 4.5mm)
HeatingMethod Long, Middle, and shortgrooves
Alarm Overheat, low temperature, system error, door open, warming upalarm
Temperature: 5 to 30?
OperationalEnvironment Humidity: 20 to80%
Atmosphere: 76.0 to 106.0kPa
Temperature: 20 to 55?
Transportation and StorageEnvironment Humidity: 10 to93%
Atmosphere: 50.0 to 106.0kPa
Display LED
InstallationMethod IV knob, Hangeroptional
WorkingMode Continuousheating
ProtectionClass Class II, Type CF,IPX1
PowerConsumption 85VA
Input:100-240V(ACpower),50/60Hz,0.3to0.7A Output: 12 V
PowerSupply
(DC power, 2.5 A)
Dimension (L × H ×W) 180 × 70 × 35mm
NetWeight 0.2kg
GrossWeight 0.4kg
156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN,Uk
Email:[email protected]| Website:www.medicaldeals.com| Phone:+1 506 6990674