Uploaded on Apr 16, 2025
Medical Deals Blood and Infusion Warmer provides a temperature range of thirty-two to forty-two degrees Celsius with rapid warming in under four minutes. It supports standard single-use tubes and a clear seventy-two by seventy-two millimeter display and ensures safe heating with multi-level.
Blood-and-Infusion-Warmer-MD-BIW-1002
Blood and Infusion Warmer MD-BIW-1002
Overview:
Blood and Infusion Warmer MD-BIW-1002 offers a temperature range of 32.0 to 42.0 ?. It provides rapid warming in
less than 4 minutes and has a clear 72 × 72 mm display for easy monitoring. It features direct and efficient heat transfer tothe
patient. It has a compact, straightforward design with a direct digital display to enable simple operation. It is widely used before,
during, and after surgeries as well as in ICU, NICU, Pediatric, Emergency, and Outpatient departments. This device provides rapid,
controlled warming to stabilize body temperature and manage patient hyperthermia.
Features:
P o r t a b l e , C o m p a c t D e s i g n
U s e r - F r i e n d l y L C D D i s p l a y
M u l t i p l e TemperatureControlProtection
M e d i c a l - G r a d e S i l i c o n e
H e a t i n g P r o f i l e V a r i e t y o f
H e a t i n g P r o f i l e s A v a i l a b l e
D r y H e a t i n g f o r Q u i c k S e t u p
D i s p l a y s Temp,Time,Alarms,Status
M u t e F u n c t i o n f o r 2
M i n u t e s
Applications:
TheB l o o d a n d I n f u s i o n W a r m e r M D - B I W -
1 0 0 2 i s w i d e l y u s e d i n h o s p i t a l s , s u r g e r i e s , I C U , N I C U , p e d i a t r i c , e m e r g e n c y
d e p a r t m e n t s , t r a u m a c a r e , a n d a m b u l a n c e s , p r o v i d i n g r a p i d b l o o d w a r m i n g t o
m a n a g e b o d y t e m p e r a t u r e a n d p r e v e n t h y p e r t h e r m i a .
Specifications:
Standardsingle-usePVCbloodorIVtubes(diameter:3.5to7mm,supportsdifferentheatingprofiles)
Compatible IV/BloodSets
DisplaySize 72 × 72cm
OperationalMode Continuousheating
HeatingTechnology Dry silicone heatingprofile
PreheatingTime ?4min
HeatingDuration 00h00min to99h59min
32.0 to 42.0?
TemperatureRange
86.9 to 107.6?
?±1?
TemperaturePrecision
?±1.8?
0.1?
TemperatureIncrement
0.2?
UnitOptions ? /?
SafetyClassification Class II, Type CF,IPX4
OverheatSafety 50±5 ?, hardware and softwareprotection
AlertTypes Overheat, low temperature, system error, overtime, preheatingalarm
Temperature: 5 to 30?
OperatingEnvironment Humidity: 20 to 93%
Atmosphere: 70.0 to 106.0kPa
Temperature: -20 to 55?
StorageandTransportConditi
Humidity: 10 to 95%
ons
Atmosphere: 50.0 to 106.0kPa
PowerConsumption 80VA
PowerSupply 100 to 240 V, 50/60Hz
Dimensions 155 × 110 × 170mm
Weight 1.2kg
156 Great Charles Street, Queensway, Birmingham, West Midlands B3 3HN, Uk
Email:[email protected]|Website:www.medicaldeals.com|Phone:+15066990674