H12-425 - Huawei Practice Exam Dumps, Exam4Lead.com


Daisylaura175

Uploaded on Jun 28, 2020

Category Education

Our experts have done their best to design H12-425 dumps for the preparation of IT students. This material has helped a lot of candidates to pass their certifications with reasonable marks. Exam4Lead is providing this material. You just need to visit the site and download the demo questions. All the necessary information regarding the field has been filled in H12-425 exam dumps which will make you able to answer each question in the final test. This dumps material is available in PDF format for the best reading experience.

Category Education

Comments

                     

H12-425 - Huawei Practice Exam Dumps, Exam4Lead.com

H12-425 ICT Professional - Data Center Facility - Build Facility Deployment Optimization https://www.exam4lead.com/huawei/h12-425-dumps.html QUESTION 1 Site selection is one challenge for the traditional data center A. TRUE B. FALSE Correct Answer: A Section: Huawei data center facility Explanation Explanation/Reference: TRUE QUESTION 2 Unpredictable business, expansion and difficult investment is one of the challenges facing the development of traditional data center business. A. TRUE B. FALSE Correct Answer: A Section: Huawei data center facility Explanation Explanation/Reference: QUESTION 3 Which system affects the PUE most in Data Center. A. Power Distribution system B. Cooling System C. N/A D. Lighting system Correct Answer: B Section: Huawei data center facility Explanation Explanation/Reference: QUESTION 4 Which one is the best PUE in the following: A. 1.06 B. C. 20.3 D. -0.5 Correct Answer: A Section: Huawei data center facility Explanation Explanation/Reference: https://en.wikipedia.org/wiki/Power_usage_effectiveness QUESTION 5 Cold/Hot aisle containment is used to solve the problem of heat dissipation in Data Center. A. TRUE B. FALSE Correct Answer: A Section: Huawei data center facility Explanation Explanation/Reference: QUESTION 6 Modular Data Center is on-demand deployment, which avoids over-investment. A. TRUE B. FALSE Correct Answer: A Section: Huawei data center facility Explanation Explanation/Reference: QUESTION 7 Which Technologies or solutions can reduce PUE? A. Increasing the number of access control systems B. Efficient modular UPS C. Cold/hot aisle containment D. In-row cooling Correct Answer: BCD Section: Huawei data center facility Explanation Explanation/Reference: QUESTION 8 FusionModule2000 is an outdoor smart modular data center solution. A. TRUE B. FALSE Correct Answer: B Section: Huawei data center cooling system Explanation Explanation/Reference: FusionModule2000 is an indoor model QUESTION 9 FusionModule1000 is an indoor prefabricated all in-one data center solution. A. TRUE B. FALSE Correct Answer: B Section: Huawei data center cooling system Explanation Explanation/Reference: FusionModule1000A All-in-One Prefabricated Data Center is a green and reliable outdoor data center solution. QUESTION 10 FusionModule1000A series solution meets the TIER 4 requirements if it adopts 2N power supply and distribution system. A. TRUE B. FALSE Correct Answer: B Section: Huawei data center cooling system Explanation Explanation/Reference: (FM1000A does not support Tier 4) https://www.exam4lead.com/huawei/h12-425-dumps.html