How Often Should Your Fire Sprinkler Systems Be Inspected And Tested?
HOW OFTEN
SHOULD YOUR
FIRE
SPRINKLER
SYSTEMS
BE
INSPECTED
AND
Fire Sprinkler Systems have set a benchmark of exceptional fire safety and protection.
Almost all residential and office
buildings have ensured (and
are ensuring) to install a fire
sprinkler system at their
premises. The automatic
operation of these systems
serves to be the first line of
defense in the worst-case
scenarios that is when a fire
does indeed break out.
These fire sprinkler
systems are, therefore,
dependable. quite
And when such a reliable arrangement constitutes to be an imperative component of
your fire safety plan, it is quite necessary to get it regularly inspected and tested, to
make sure that it continues to perform optimally. So, if you are a business owner or
facilities manager, you should be informed on how often you should be getting your
sprinkler systems inspected and tested.
In this article, we’re going to furnish you with a general overview of these particular
specifics and details:
How Often Should Fire Sprinklers Be Inspected?
All the components of a fire sprinkler system, based on their functioning, require to
be inspected at different time
intervals.
The following are the
recommended time intervals of
inspection of the different
elements of a sprinkler system:
Weekly To Monthly
Gauges are a vital component of
a fire sprinkler system. They help
to ensure that the system is
active and in service. They also
check that proper water supply
and pressure are available.
Temperature Gauge Therefore, gauges need to be
Float Switch inspected as much as once a
week to make sure that they are
System Supply Valve fit for the purpose, whether we
Security Lock talk about dry, pre-action, and
Heating Element (behind alarm) deluge systems.
However, the wet pipe gauges
System Alarm Test Button
can go as far as one month
System Alarm without requiring another
System Drain Valve
Pipe Cap
inspection.
Quarterly
Once every three months, the water flow alarm devices, signal devices, valve alarm
devices, hydraulic data plates, control valves, and fire department connections of the
sprinkler system must be extensively inspected.
Annually
An annual testing and or flow test constitutes the monitoring of pipework and fittings,
signage, hanger/seismic bracing, and the fire sprinkler system as a complete unit, itself.
Every Five Years
It is highly recommended to inspect all internal pipework concerning the entire
installed unit of a fire sprinkler system. The blockages must be checked as well.
And, other components, as per their functioning, and requirement should too be
serviced.
How Often Should Fire Sprinkler Systems Be Tested?
First of all, let us tell you the
difference between
inspections and testing of
fire sprinkler systems.
Inspections are
fundamentally visual checks,
whereas testing involves
actual physical use of the
equipment to verify whether
the component is
functioning as intended or
not.
That is the reason testing is
executed at less frequent
time intervals than
inspections.
Quarterly
It is recommended to execute a physical test on all the mechanical devices of a fire
sprinkler system. This is usually mandated by the local AHJ.
Semi-Annually
At this time, vane and pressure switch type devices must be tested every six months.
Annually
Likewise, and as bracketed under the annual inspection category, a fire sprinkler
system must be thoroughly tested, every year, as well. Technicians must physically
check each and every component of the entire unit, from water flow and fire pump to
alarm and trip tests of dry pipe, deluge, and pre-action valves. This is also usually
mandated by the local AHJ.
Every Five Years
Precautionary tests on the sprinklers exposed to either high temperatures or harsh
conditions must most definitely be conducted every five years. Gauges of all types of
sprinkler systems shall too be tested and/or replaced (as per requirement).
Every 10 Years
Dry sprinkler systems must be tested
and/or replaced after a decade. Fast-
response sprinklers should be tested
after 20 years (and subsequently, within
or after a 10-year time interval).
Standard sprinklers must be tested after
50 years and then after the succeeding
10-year interludes.
As you can see, fire sprinkler systems are
integral to the safety outlines of
numerous residential and corporate
structures. Therefore, every individual
must ensure to get their system inspected
and tested on a regular basis.
Qualified personnel and technicians must be approached to conduct the tasks. They
could efficiently and frequently monitor, re-equip, and improve the functioning of the
fire sprinkler system.