When you are selecting vacuum furnaces for your industrial application then you should consider some factors. Some factors such as weight capacity, work area, temperature consideration, vacuum performance, hot zone construction, vacuum system components, furnace chamber design, electrical equipment & controls, etc. So make sure to look into each factor before selecting vacuum furnaces for your industrial application. For more details visit:- https://www.launchora.com/story/what-factors-you-should-consider-fully-when-select
What Factors You Should Consider Fully When Selecting Vacuum Furnace for Your Application?
What Factors You Should Consider Fully When
Selecting Vacuum Furnace for Your Application?
Want to invest in vacuum furnace for brazing? Or for
vacuum heat treatment, vacuum sintering, annealing,
thermal processing in your industrial application? All these
are extremely important procedures and must be executed
with the finest furnace.
If you start scouting for vacuum furnaces, then you will see
that there are hordes of options available – including
graphite crucible & wafer, tungsten crucible & wafer in
laboratory vacuum furnace, as well as tungsten crucible &
wafer, graphite crucible & wafer in benchtop furnace.
Considerations to Make When Shopping for Vacuum
Furnace?
Weight Capacity
Work Area
Temperature Consideration
Vacuum Performance
Hot Zone Construction
Vacuum System Components
Furnace Chamber Design
Electrical Equipment & Controls
Power Supply
Gas Cooling System
Weight Capacity
You need to ensure what maximum load weight at a
specific elevated operating temperature can be
processed.
Work Area
What load size can be processed is the consideration
for determining the effective work area. This is
important so you are able to buy fit-size furnace hearth
and not larger than that because it will increase
operating cost.
Temperature Consideration
What your requirement is pertaining to high temperature
furnaces operation? This is an important consideration.
Most furnaces come with a capability to operate at
2400°F, while for higher requirement added temperature
capability can also be availed.
Temperature operating uniformity across the furnace
range should be looked into, exploring all the options.
Vacuum Performance
For blower/mechanical pump furnace, ultimate vacuum is
in range of 20 Microns Hg or more. For diffusion pumped,
ultimate vacuum range is 10‐6 Torr.
There should be approximate 10 minutes time period
from pump-down to high-vacuum cross-over.
Hot Zone Construction
Acceptable insulation package has to be considered
based on the industrial standards pertaining to thick 304
stainless steel structure and flaxshield. This is important
to reduce moisture absorption and reduce chances of
oxidization and rusting.
Heating element insulators must be used in a way that
these are protected from contaminating vapors.
Vacuum System Components
The mechanical pumps have to be of high quality, and
must provide for large reservoir for efficient functioning
during hot & humid days.
Vacuum blower pump is also another important
component that has to be considered with good research.
Furnace Chamber Design
The basic construction of the furnace design has to be
well thought out. It must conform to the industry
standards and codes, and must be able to properly allow
water circulation.
The chamber door design must be like it allows for proper
personnel safety during the autoclave movement. The
door should be able to avoid seal failure and dirt
collection.
Electrical Equipment & Controls
A centralized, easy to operate cabinet, conforming to the
industry standard, is important to house the electrical
controls.
For proper control and monitoring of the furnace, a
cabinet that houses temperature controller,
programmable controller and other controllers and
recorders for smooth operation is much-needed.
Power Supply
An advanced power supply with complete controls
including the trim control has to be provided within the
cabinet. It must be able to remove any possibility of
power flow problem in the transformer.
Gas Cooling System
Both internal and external cooling systems have to be
considered fully, so these are able to provide easy access
to heat exchange, drive motor, eliminate drive motor shaft
rotating seals.
Gas nozzles have to be optimum in allowing for
accelerated gas flow, and ensure proper functioning
throughout the hot zone & front door main section.