Uploaded on Jul 9, 2025
Medlon Ventilator System features a 15-inch TFT LCD touch screen, power input of 250–900 VA, and supports multiple ventilation modes. It operates with an air compressor, uses oxygen and air sources, and offers oscillogram displays for detailed respiratory analysis.
Ventilator-System-MVS-702
Ventilator System MVS-702
www.medlon.com | [email protected]
Description:
Ventilator System MVS-702 features 15-inch TFT LCD touch screen
for user-friendly interaction. With a power input ranging from 250
VA to 900 VA, it is capable of delivering high-quality ventilation
support across a broad spectrum of medical environments. It offers
various ventilation modes, allowing for tailored respiratory support
based on patient needs. This system operates with an air
compressor and requires a gas source of oxygen and air.
Additionally, it offers a variety of oscillogram displays, allowing for
detailed analysis of the patient’s respiratory status.
Specifications :
PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV,
Ventilation Modes P-A/C, V-A/C, IPPV, PCV, PSV,
SPONT/CPAP, SIGH, MANUAL
Ventilator Tidal Volume (Vt) 20 to 2000 mL
Ventilator Frequency (Freq) 1 to 100 bpm
Ventilator Oxygen Concentration 21% to 100%
Ventilator I:E Ratio 4:1 to 1:8
Ventilator PEEP 0 to 40 cmHO
Ventilator Pressure Trigger
-20 to 0 cmHO (based on PEEP)
Sensitivity
Ventilator Flow Trigger Sensitivity 0.5 L/min to 30 L/min
Ventilator Pressure Control (PC) 5 to 80 cmHO
Ventilator Pressure Support (PS) 0 to 80 cmHO
Ventilator SIGH Off, 1/100 to 5/100
Apnea Ventilation Off, 5 s to 60 s
Ventilator Pressure Limit 20 to 100 cmHO
Monitoring Frequency 0 to 100/min
Monitoring Tidal Volume (Vt) 0 to 2500 mL
Monitoring MV (Minute Volume) 0 to 99 L/min
Monitoring Airway Pressure 0 to 100 cmHO
Monitoring Dynamic Lung
1 to 1000 mL/cmHO
Compliance
Monitoring Oxygen Concentration 15% to 100%
Power Failure Alarm on AC power loss
Battery Low Voltage d 11.3 – 0.3 V
No Tidal Volume Alarm within 6 s
High/Low Minute Volume 5 to 99 L/min / 1 to 30 L/min
High/Low Airway Pressure 20 to 100 cmHO / 0 to 20 cmHO
High/Low Oxygen Alarm 19% to 100% / 18% to 99%
Continuous Pressure (PEEP + 1.5 cmHO) >16 s
Suffocation (5 to 60 s)
Other Alarms Fan Error
Oxygen Deficit
Max Limited Pressure < 12.5 kPa
Display 15
Oscillograph Display 3 of 5 can be shown simultaneously
Alarm Types 14 Visual/Sound Alarms
Casters 4 Wheels, 2 Brakes
Gas Source O, Air
Pressure 280 to 600 kPa
Voltage 220 V – 22 V
Power Frequency 50 Hz – 1 Hz
900 VA (with compressor)
Input Power
250 VA (without)
Oscillogram Types P-T, F-T, V-T, P-V, F-V, P-F
Air Compressor Dimensions (L × W ×
685 × 690 × 1140 mm
H)
Main Engine Dimensions (L × W × H) 560 × 560 × 615 mm
Air Compressor Net Weight 63 kg
Air Compressor Gross Weight 98 kg
Main Engine Net Weight 19 kg
Main Engine Gross Weight 32 kg
Features :
Multiple Ventilation Modes
Adjustable Parameters
Advanced Monitoring
Alarm System
Oscillograph Display
Sigh Function
Apnea Ventilation
Continuous Pressure Monitoring
Compact and Mobile Design
User-Friendly Interface
Gas Source
Applications
Our Ventilator System MVS-702 is ideal for use in intensive care units
(ICUs), emergency departments, and operating rooms, where
patients require precise and reliable ventilation. It is suitable for
adults, pediatrics, and neonates, supporting various ventilation
modes tailored to individual patient needs.
Medlon Equipment Ltd.
Email: [email protected] | www.medlon.com