Semi-automatic Bio-chemistry Analyzer also known as chemistry analyzer is a compact, semi-automated and high performance analyzer comprises 8 assay modes offers photometric range from 0 to +3.0 OD with 3 level temperature range along with temperature accuracy of ±0.1˚C. Incorporated with excellent QC function with large memory. Equipped with different wavelengths such as 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm with accuracy of ±2nm. Built-in thermal printer with Real time graph display.
Semi-Automatic-Bio-Chemistry-Analyzer
SEMI-AUTOMATIC BIO-CHEMISTRY
ANALYZER LSBA-A20
[email protected] www.labtron.com
Semi-automatic Bio-chemistry Analyzer LSBA-A20
Semi-automatic Bio-chemistry Analyzer LSBA-A20 also known as chemistry analyzer, semi-automated and high
performance analyzer comprises 8 assay modes offers photometric range from 0 to +3.0 OD with 3 level temperature
range along with temperature accuracy of ±0.1˚C. Incorporated with excellent QC function with large memory.
Equipped with different wavelengths such as 340nm, 405nm, 492nm, 510nm, 546nm,578nm, 620nm with accuracy of
±2nm. Built-in thermal printer with Real time graph display.
FEATURES
Two test mode: flow-cell or cuvette
Supports bi-chromatic tests for end point, fixed-time, kinetics methods
E xternal keyboard or mouse support via USB
U ser-friendly interface and multi-language operation software
7 inch back illuminated color touch panel; LCD display with in-built thermal printer
20 incubating positions
Equipped with both Monochromatic & Bi-chromatic measurement with 6 filters and 2 free positions.
Halogen lamp as light source with long life span
Easy to use with low maintenance
APPLICATIONS
Semi-automatic Bio-chemistry Analyzer is used across molecular biology, biotechnology, immunology, microbiology,
routine biochemistry, hormonal assay, electrolytes, therapeutic drugs and drug-enzyme investigations.
SPECIFICATION
Model LSBA-A20
Measuring Range: 0 to 3.0 OD
Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard,
Two point Non Linear, and Sample Blank Non Linear
Measuring System
Photometric linearity: ±2% (0 to 3.000 OD)
Photometric accuracy: ±1% (0 to 3.000 OD)
Carry over: ≤1%
Light source: 6 V, 10 W halogen lamp; standby function
Photometric System Filters: 340 nm,405 nm,492 nm,510 nm,546 nm,578 nm, 620 nm and 2 more open
filter positions (on request)
Wavelength Accuracy: ±2 nm
Temperature: 25˚C, 30˚C, 37˚C
Thermostatic Control
Precision: ±0.1˚C
Drift
Comments