Introduction:
Smoke alarm is one crucial technology that protect you
and your property from the unwanted damages and keep
it safe.
This document will let you know about some important
factors you must know about smoke alarm when installing
a new or replacing an old one.
Factors to Check When Smoke Alarm is
Activated
• The Battery
• Insects and dust or dirt
• Smoke alarm placement
• Power interruptions
• Extremely humid conditions
• Routine maintenance
• Silence or hush your smoke alarm
• Smoke alarm controller
The Battery: When the smoke alarm's battery is low and has to be
replaced, it will give indication at regular interval in every 40
seconds.
Insects And Dust or Dirt: These kind of particles could set off a
false alarm. Use vacuum cleaner on monthly bases to clean the dirt
and insects which is present on the surface of alarm.
Placement: Smoke alarm close to kitchen, bathroom can trigger
false alarm due to steam. Ensure smoke alarm rightly placed far
from the area such as kitchen, bathroom and laundries as well.
Power Interruptions: When electricity is interrupted, smoke alarms
may sound for a brief period of time. When electrical providers
switch grids early in the morning, there is an electricity spike, or
electricity is interfered via a common circuit, power disruptions
might occur.
Extremely Humid Conditions: Due to dense humid air condition
smoke alarm can trigger false alarm. Step can be taken over so that
it can work in the adverse climatic conditions.
Original Source: Emerald Alarms Troubleshoot
Routine Maintenance
• Weekly Alarm: you can test by pressing the test button on the cover of
smoke alarm. If no alarm then there is immediate call of action should be
taken on battery.
• Monthly Cleaning: Use the vacuum cleaner with a soft brush to clean
particles present on the cover and sides of the alarm system.
• Yearly: To ensure peace in your hectic schedule we recommend a
yearly safety .
Original Source: Emerald Smoke Alarms Manual
Silence or Hush Your Smoke
Alarm
If you have ensured there is no fire at the property please take
following steps to silence or hush your smoke alarm:
• Press and release the silence button.
• Your alarm will silence and enter a reduced sensitivity reset
cycle for approximately 8 minutes.
• During the reduced sensitivity reset cycle, the LED light will
flash every 8 second.
• Your alarm will atomically return to full sensitivity on completion
of the reset.
Smoke Alarm Controller
We recommend the installation of an Emerald Smoke Alarm
controller which allow you to test, and locate triggered without
reaching the alarm on ceiling. It also locates all issues arising in
alarm system by just pressing the locate function.