Uploaded on May 31, 2021
The Thermo ScientificTM OrionTM 8010cX Online Ammonia Analyzer is based on the EPA-approved standard method of salicylic acid spectrophotometry, which is reliable, traceable and does not require toxic reagents. Vsit https://bit.ly/2SB7rT8 for more info.
Orion 8010cX Ammonia Analyzer – IC Controls
DATASHEET Orion 8010cX Online Ammonia Analyzer Orion 8010cX Ammonia Analyzer The Thermo Scientific™ Orion™ 8010cX Online Ammonia Analyzer is based on the EPA-approved standard method of salicylic acid spectrophotometry, which is reliable, traceable and does not require toxic reagents. With a state-of-the-art industrial design that boasts an intuitive user interface and an anti-interference measurement process algorithm, the Orion 8010cX Ammonia Analyzer can be utilized in various applications to meet regulatory compliance and process control requirements. Part of the flexible Thermo Scientific™ Orion™ 8000 Series Analyzer Platform that enables monitoring for multiple parameters through one simple interface, the The Orion 8010cX Online Ammonia Analyzer Orion 8010cX Analyzer delivers high performance, ease of setup and reliability. Overview Ammonia is one of the most common pollutants in our Market waterways. Its direct impact on the environment and • Municipal wastewater • Drinking water indirect harm (such as eutrophication) caused by the contribution of nitrogen after its discharge into natural • Surface water • Industrial wastewater water bodies are a source of concern. Many government agencies have strict regulations around the discharge of Applications ammonia, which is one of the main monitoring indicators • Municipal sewage: online monitoring, sewage treatment in sewage discharge standards. As a result, ammonia facility influent and effluent monitoring measurements are included in one of two aggregate control targets, which were introduced 15 years ago in • Surface water: water sources to include lakes, reservoirs China. In order to meet the discharge standard, in addition and other online monitoring to the emission target control monitoring of the discharge • Drinking water: quality control of disinfection process and outlet, each sewage discharge facility must strictly control online monitoring of drinking water the ammonia concentration during each stage of the sewage treatment process in order to adjust the relevant • Industrial wastewater: process control process parameters for treatment. Without this in place, it is extremely difficult to meet final discharge requirements. Online detection technology enables organizations to Orion 8010cX Online Ammonia Analyzer specifications obtain ammonia monitoring data quickly and accurately 1. The salicylic acid colorimetric method for and provides the foundation for ammonia emission the measurement of ammonia is a method supervision. However, accurate and reliable monitoring approved by the EPA. instruments must meet multiple needs and requirements. When dealing with complex sewage conditions, the 2. Measurements can be performed in continuous or equipment must withstand the pollution from sewage to the interval mode for additional flexibility. equipment, and, at the same time, it must exclude these 3. Five measurement ranges of 0.02–2 mg/L, interference factors and provide accurate data. In addition 0.1–15 mg/L, 0.5–30 mg/L, 2–100 mg/L and to meeting these requirements, the Orion 8010cX Online 30–500 mg/L are standard. The instrument can switch Ammonia Analyzer is equipped with functions such as ranges without recalibration. The working range can automatic range switching, calibration and cleaning also be selected manually in the menu interface. to ensure long-term and stable unattended operation of the instrument. 4. The analyzer uses low water sample volumes in harsh working environments, reducing sample waste. Our new ammonia analyzer is designed to provide accurate and stable online ammonia detection solutions for complex 5. Multi-featured menu with a user-friendly interface. applications. The instrument combines an EPA-approved 6. The analyzer has multi-input and output capability, measurement method, multiple features, an intuitive including 2 digital inputs, 2 programmable relay menu interface and low maintenance all of which provide outputs, 2 isolated 4–20 mA outputs and standard application flexibility and an enriching user experience. MODBUS output. Digital inputs and programmable relay outputs can be used to control external pumps, Advantages valves and pretreatment. The MODBUS register • The aim is to provide accurate and reliable addresses can satisfy routine data transmission and measurements to meet emissions regulations and allows customers to obtain the specific state of the process control requirements instrument remotely. • Automatic range switching function ensures data validity 7. The instrument has an automatic calibration function and accuracy to reduce maintenance cost. Once the calibration is • Multiple software functions, intuitive graphical operation complete, the analyzer is back on-line. interface, easy to understand and operate 8. Auto clean function allows the entire fluidic system • Incorporated is a special test flow design and an to remain clean, while generating a small amount of algorithm to remove interferences (color and chemical waste (
Comments