Benchtop-Multi-Pipe-Centrifuge-BZBM-503


Emmasmith

Uploaded on Aug 20, 2025

Category Business

Labzee Benchtop Multi-Pipe Centrifuge with microcontroller-controlled brushless AC motor 5-inch LCD display, 4×100 ml capacity and up to 5000 rpm speed Features RCF up to 3920×g, gas pivot lid protection and real-time error alerts for reliable performance

Category Business

Comments

                     

Benchtop-Multi-Pipe-Centrifuge-BZBM-503

Benchtop Multi Pipe Centrifuge BZBM-503 www.labzee.com | [email protected] Description: Benchtop Multi Pipe Centrifuge BZBM-503 is having microcontroller- controlled brushless AC motor system. The 5-inch LCD screen displays the parametric ranges. It has a capacity of 4×100 ml and a speed range of 0 to 5000 rpm, as well as a lid drop protection with a gas pivot. It has an RCF of 0 to 3920×g, instantaneous errors, and screen alerting identification. Specifications : Speed Range 0-5000rpm adjustable Maximum Capacity 4×100m1 RCF Range 0 to 3920×g adjustable Time Range 1-99minutes adjustable Speed Accuracy – 20r/min Power Supply AC220-240V,50/60HZ,5A,0.5KW Noise 58dB(A) Dimension 510×400×280mm Net Weight(Without Rotor) 30kg Features : It is having brushless AC Motor with Microprocessor Control Pre-cooling performs in a CFC-free cooling system The LCD, the screen shows the speed, timer, RCF, temperature, rotor information, Program (Memory) information, acceleration, and deceleration information, and error code information The stainless steel centrifugal force body and chamber are autoclavable and resistant to detergents and disinfection liquids Lid drop protection with a gas hinge Safety when the rotor is running, the door will not open, and the machine will not run if the lid is open, resulting in an error code The lid lock releases automatically when the power goes out For speed measurement and noise measurement, there is a window on the lid Continuous operation, working in accordance with the time table by different types of programs (memory) and ten different types of acceleration (deceleration) to choose from Automatic troubleshooting with a runtime error and alerting identification on the screen Autoclaving can be used on a variety of rotors Rotors : Maximum RCF ×g RotorName Maximum Speed(rpm) Maximum capacity (ml) Swing Rotor 01 4000 16×10/15ml 2780 Swing Rotor 02 4000 24×10/15ml 2780 Swing Rotor 03 4000 4×50ml 2780 Swing Rotor 04 4000 4×100ml 2780 Fixed 5000 12×15ml 3920 Applications : Applications in molecular biology or cell culture and Laboratories 1938 E Harney St, Laramie, WY 82072, USA Email: [email protected] | Website: www.labzee.com