Uploaded on Apr 7, 2025
Labzee Gas chromatography system features a 22L oven with a 5 °C to 400 °C range, constant pressure flow and three carrier gas controls. It includes FID and TCD detectors and a 7-inch touchscreen for precise bidirectional control, enabling analysis of varied samples and concentrations.
Gas-Chromatography
Gas Chromatography
BZGC-501
www.labzee.com | [email protected]
Description:
Gas Chromatography BZGC-501 is equipped with a 22L oven and
operates within a temperature range of 5°C to 400°C. It is designed with a
constant pressure flow mechanism and accommodates 3 individual
carrier gas flow control systems. Features FID and TCD detectors for
versatile analysis of diverse sample types and analyte concentrations. It
is integrated with a 7-inch color touchscreen for bidirectional control of
variable parameters.
Specifications :
Software N2000 (Only for data
recording)
Optional Accessories Hydrogen generator
Nitrogen Generator
Air Generator
Oven Capacity 22 L
Oven Temperature Range RT + 5 to 400
Temperature Accuracy – 0.1
Temperature Program 9 Step
Program Total Time 9999.9 min
Maximum Heating Rate 0.1 to 60 / min
Maximum Cooling Rate d 10 mins (250 to 50 )
Sample Injector Temperature Range RT+ 7 to 420
Temperature Control Independent
Injector Type Column or split
Maximum Sample Inlet 3 pcs
Carrier Gas Flow Type Constant pressure
Column Pressure Range 0 to 400 kPa
Column Pressure Accuracy 0.1 kPa
Detector FID and TCD
Temperature Range RT + 7 to 420
Maximum Installation Dual detector
Flame Ignition Mode Automatic
Logarithmic amplifier
High voltage switch control
Flame Ionization Detector (FID)
Baseline signal display
Ignition coil control
FID Detection Limit d3 ×10 -12 g/s (Sample: n-hexadecane)
FID Baseline Noise d 5 × 10 - 14 A
FID Baseline Draft d 6 × 10-13
FID Dynamic Range 10 7
FID RSD d 3 %
Sensitivity : 8000mV.ml/mg (Sample: n-
Thermal Conductivity Detector(TCD)
hexadecane)
TCD Baseline Noise f0.5mV
TCD Baseline Draft d 0.15 mV/30 min
TCD Dynamic Range 10 u
Power Supply AC 220 V – 22 V, 50 Hz – 0.5 Hz
Power Consumption 3000 W
Packing Dimension 1020 × 660 × 740 mm
Gross Weight 82 kg
Net Weight 70 kg
Features :
One key start-up function
Auto self-check & malfunction identification
32-bit embedded hardware system
8 external event interfaces for valve control
Supports data storage
Applications :
Gas Chromatography is widely utilized in research, industrial monitoring,
environmental monitoring, aerospace, etc.
Labzee Scientific, 21010 Southbank Street, Sterling,
VA 20166, USA
Email: [email protected] | Website: www.labzee.com
Comments