Uploaded on Jun 23, 2020
The IEC/EN 61439 is the result of the work of technical committees and subcommittees composed of representatives of the full member national electrotechnical committees in Europe, each dealing with a particular subject in the entire range of Electrical products and assemblies. IEC standard 61439 covers low voltage switchgear and control gear assemblies. It is a replacement for the earlier IEC standard 60439 and is now the industry standard requirement for all low voltage switchgear and control gear panel assemblies. The new standard gives details on the requirements of products through testing and other verification methods especially at pre design stage.
Benefits of Using IEC 61439 Standard in Electrical Busbar Systems
IEC 61439 Standard in
Electrical Busbar systems
www.messungelectricalengineering.c
om
Preface
In the Electrical manufacturing industry ‘Standards’ which define clear rules are extremely necessary for safety, proper
functioning & to ensure quality at all levels. All the rules and recommendation under standards have been derived through
extensive real world testing which assures correct or proper functioning of an electrical installation.z
Not adhering to standards can result into grave electrical hazard affecting the end user. Following standards ensures safe
operation of the electrical installation for many years.
Introduction
The IEC/EN 61439 is the result of the work of technical committees and subcommittees composed of representatives of the full
member national electrotechnical committees in Europe, each dealing with a particular subject in the entire range of Electrical
products and assemblies.
IEC standard 61439 covers low voltage switchgear and control gear assemblies. It is a replacement for the earlier
IEC standard 60439 and is now the industry standard requirement for all low voltage switchgear and control gear panel
assemblies. The new standard gives details on the requirements of products through testing and other verification methods
especially at pre design stage.
www.messungelectricalengineering.c
om
Why was the new standard created?
In the earlier IEC standard 60439, ‘Design verification’ was excluded, and therefore the respective roles of equipment
manufacturers and panel builders were not clearly defined, so responsibility for ensuring compliance was equally difficult to
pinpoint. .
How does this new standard add value to the OEM, Consultant,
Designer and Panel Builder?
The designer, be it from the consultant, OEM or the Panel builder identifies the needs and constraints for design, installation,
operation and up-gradation of the complete system right at the design stage.
He chooses the correct switch gear, cables, connectors, busbar products and other components as per the specifications that he
intends to use in his final assembly. Before he takes it up for manufacturing, at the design stage itself he needs to be sure that his
choice of components are proper and that when the components are fitted in the control panel or Distribution panel that they
follow the IEC 61439 standard.
To ensure this the designer carries out the design verification by various software tools provided by manufacturer which allows the
electrical designer to be sure of his installation at an early stage.
1) The verification of the design by actual testing himself or by third party labs & by the calculation via prescribed tools supplied
by the product manufacturer.
2) Proper documentation of this design verification (e.g. test documentation, calculations) is then made by the prescribed tools
provided by the manufacturer.
www.messungelectricalengineering.c
om
The panel builder thus is not only responsible for the completed assembly but also responsible for:
• The rating of the switchgear assembly according to the customer requirements.
• The compliance with the design verification of the original manufacturer.
• The declaration of conformity to the customer (Declaration of Conformity)
• The marking and documentation of the assembly
• The performance of the design verification and documentation
General information about IEC - 61439
In IEC 61439 three verification methods are recommended
• First by test
• Second by comparisons
• Third with reference to design & by assessment.
This covers Assemblies integrated for Generation, Transmission & Distribution of Electrical Energy and assemblies designed for
Electrical equipment all in the voltage range not exceeding 1000V AC or 1500V DC.
www.messungelectricalengineering.c
om
Wöhner Busbar System and IEC 61439 standards
Wöhner has been synonymous with top performance and innovation in
technology for over 88 years. With over 100 registered patents, the Wöhner
group is well established worldwide as a competent and reliable partner for
energy distribution, control technology and renewable energies.
Wöhner has made it easier for electrical designers to adopt the new standard
through verification methods by specially designed software tools on their
website, which can be used for saving costs & need for additional testing.
• Short circuit strength: Pre calculated & tested by third party (avoids
own testing requirements)*
• Temperature rise test: Pre calculated & tested by third party (avoids
own testing requirements) Cross Board Classic
• Current insulation: Creep-age distance and isolation voltage pre-tested
according to standards
• Dielectric strength: By specification in product data sheet ( Flexible
Busbar )
*If short circuit values are not taken in to consideration, during
electrical fault there would be a serious fire hazard, harmful to
everyone.
60 Classic
Wöhner provides the current carrying capacity of the busbar and short circuit
withstand capability of the system by calculation method with special tools on
twhwe w.embseitses.ungelectricalengineering.c
om
`
1. Tools for achieving IEC 61439
Wöhner provides following free online tools which can be used by designer/planners verify their own design and confer to all the standards
under IEC 61439
1) Software for own design verification making the installation IEC complaint
2) Configurator tool to design and achieve the required Short circuit withstanding capability
3) Current carrying capacity of a Busbar & busbar holder with respect to temperature of busbar & enclosure
4) Di-electric strength of the assembly of Busbar in the electrical enclosure
Software for own design
verification making the
installation IEC complaint:
Wöhner provides special software
which can be accessed under their
website menu “Tools” where
designer can fill up the Verification by
comparison with a reference
construction using the checklist under
this tool. And documentation can be
made for final submission to end user
conferring to IEC requirements.
www.messungelectricalengineering.c
om
2. Configurator tool to design and achieve the
required Short circuit withstanding capability
A snap shot of configurator tool
to achieve desired level of short
circuit rating;
Wöhner configurator tool can be
used to construct the power
distribution and to achieve and
maintain the desired short circuit
withstanding capability of the
system
www.messungelectricalengineering.c
om
3. To measure the Short circuit carrying capacity of a Bus bar
system
We can check short circuit strength of a Busbar
system by the design tools provided by Wöhner by
the following simple steps:
The short circuit strength mainly depends on few
parameters like size of the busbar, number of
supports and distance between the busbar supports.
Example:
Using the “design” tools by Wöhner we select the
busbar support in the 60Classic 3P range (01500
Wöhner part number) busbar size of 20mmx10mm,
Decide that we will be using two numbers of busbar
supports and that the distance between number of
supports will be 300 mm by giving these inputs in
the “design” tools we receive the short circuit
strength of 53 KA. (refer screen shot 1)
www.messungelectricalengineering.c
om
If we now change the
distance between busbar
support from 300 mm to 450
mm by maintaining all other
parameters same we receive
short circuit strength as 43
KA.
www.messungelectricalengineering.c
om
4. Current carrying capacity of Busbar systems by “design”
tools
We can check the “Current carrying For example
capacity” of the Busbar systems by if we select busbar to be of the size 20mm x10mm, with a length of 2.4m – (Wöhner item
the “design” tools provided by code -01624), and if we select air temperature of 35°C and busbar temperature of 85°C, we
Wöhner by the following simple will get the current carrying capacity 652A. (refer screen shot 3)
steps.
The current carrying capacity of
Busbar depends upon the Air
temperature allowable inside the
electrical cabinet and Busbar
temperature that the end User has
prescribed as Safe to use.
On the Wöhner website, we need to
select the size of the busbar,
temperature of air permissible in
the electrical panel based upon the
user specifications and allowable
temperature of busbar as desired
by the designer and allowed by the
end user. By giving these inputs we
can get the current carrying
wcawpwac.mitye sosf utnhge eBleucsbtraicr.alengineering.c
om
Now if we keep the size of the busbar and busbar An actual application photo of the
temperature as constant and change the allowable air control panels using Wöhner products.
temperature from 35°C to 55°C. We will then receive the
calculation of the current carrying capacity of the Busbar
to be 508 A.
With Wöhner products, Usage verification can be done right
at the stage of design, Thus by using the IEC 61439 standard
and with the examples mentioned above the Designer and
the OEM manufacturer and the Electrical panel builder can
design very good quality products. The End User is then
provided a system which he can trust and be ensured about
the Safety and reliability,
www.messungelectricalengineering.c
om
Other features of Wöhner’s unique Busbar solutions:
• Innovative design by Wöhner allows mounting of electrical switch
gear directly on busbars saving expensive real estate in the electrical
panel. Wöhner products guaranty safety & ease of assembly to our
customers making the Assembly time reduce to 1/3rd of the
conventional assembly time.
• Copper Busbars are connected to cables & LV switchgear (100A-
1000A) without drilling the Busbars. Well-designed mounting adapters
& cable clamps provide a systematic & compact power distribution
panel along with all features like safety, ease of assembly, ease of
maintenance, etc.
www.messungelectricalengineering.c
om
Conclusions
“Electrical wiring & design are the most critical part of any electrical
installation. Wöhner Busbar system solution are uniquely designed as
per IEC 61439 standard, and provides for free risk free compliance to
standard with best safety, quality & cost saving.”
Farook Merchant - MD Messung Group (Mega Distributor for Wöhner Products in India.)
“Working with world class standards brings International Quality to
control panels manufactured by our customers. We are able to specify,
test & guarantee to our customer; Critical specifications like Short
circuit currents, temperature rise & di-electric strength as per IEC 61439
standard. This new standard gives details on the requirements of
Wöhner products through testing and other verification methods. It is
intended to make up for some of IEC 60439’s shortcomings.”
Shrikanth Venkateshappa - International Key Account Manager, Wöhner.