MTR11 Protection Tube RTD Assemble - Flanged | MIEPL


Mieplinstrument

Uploaded on Dec 9, 2021

Category Business

"MIEPL Protection Tube MTR11 RTD Assembly is important to protect RTD sensor from corrosion , direct flame and high flow & Pressure. This have flange process connection. keywords : Thermocouples, Industrial Thermocouples, Plastic Industry Thermocouples , Van Stone Thermowells, Sanitary Thermowells, Weld In Thermowells, Industrial RTD Sensors, Bearing RTD Sensors, Skin Type RTD Sensors, Resistance Temperature Detector, Industrial Resistance Temperature Detector, Bearing Resistance Temperature Detector, Bimetal Temperature Gauge, Insert Gas Filled Temperature Gauge, Electric Contact Temperature Gauge, Diaphragm Seal, Threaded Diaphragm Seal, Flanged Diaphragm Seal, Pressure Gauge, Standard Pressure Gauge, Differential Pressure Gauge " Get more information visit on:- www.miepl.com Our Mail I.D:[email protected], [email protected], [email protected] Contact us at:- +91-11-22014325, 22014327

Category Business

Comments

                     

MTR11 Protection Tube RTD Assemble - Flanged | MIEPL

MTR11 PROTECTION TUBE RTD ASSEMBLY Flanged MIEPL Protection Tube MTR11 RTD Assembly is important to protect RTD sensor from corrosion , direct flame and high flow & Pressure. This have flange process connection. STANDARD SPECIFICATIONS Elemen : t Pt-100, Rang c: lass B e Wire -: 2 0FEATURES S 0im...4p0le0x°,C 3 combination Sheath W: iAreISI 316  Integrated Protecting materialSheath S Tube : S 6.0 diameter Head :m mWeatherproof, IP 65,  Mineral insulated enclosureEnclosure :t h rDeiaed-ecads ct over  Transmitter mountable materialCable a: l u¾m"i nEuTm (F), 1 entry  Exchangeable insert Head N: o H. ead with female extension Protecting tube threading  Spring loaded design : AISI 316 material Protecting tube S: S ½" Sch. size Process connection :4 0 APPLICATION type Process A: d 1ju.s5t"a bRleF 150# as per ANSI connection  Chemical & Process connection :B 1A6IS.5I 304 petrochemical material :Immersion S: S 150 Length  Oil & gas applicationt Extension :m m100 Length  Water, waste- DRAWING mm water treatment Total Length  Power & Utilities Extension Length Immersion Length Termin al  Air & flue gas Protection Head Tube services  Furnaces, Kilns & Weldin Fixed / Adjustable g Flange Ovens Around REFERENCE  IEC-751 / DIN 43760 Cable Entry BX BZ BV BY BU BX BS BT Single cable entry Dual cable entry enclosures enclosures ISO 9001 : 2015 www.miepl.co 01 m MTR11 PROTECTION TUBE RTD ASSEMBLY ORDERING CODE MTR11 - PT100B - XXX - C - MF - M60 - - ML - CO BZ Pt100, Class PT 100 A A Pt100, Class PT 100 B B Pt500, Class PT 500 1. ELEMENT A A Pt500, Class PT 500 B B Pt1000, Class PT1000 A A Pt1000, Class PT1000 B B -200… XX 2. RANGE 400°C X 0…600°C XX X Simplex, 2- A Wire Simplex, 4- D Wire Duplex, 3- H 3. WIRE COMBINATION WireSimplex, 3- C Wire Duplex, 2- F Wire Duplex, 4- I Wire 4. SHEATH AISI 316 MF MATERIA SSAISI 316L L MG SS 3.0 M30 mm 5. SHEATH 5.0 M50 DIAMETER mm 6.0 M60 mm 8.0 M80 mm WP, IP 65, threaded BZ cover WP, IP 67, threaded BX cover Flame proof, IP 67, Gr IIA, BS 6. HEAD IIBExplosion proof, IP 67, Gr ENCLOSURE BT IIC WP, IP 65, Hinged BV type WP, IP 65, cover fitted with 2 BY screw Ex-Proof to CSA,FM,ATEX [EEx- BU d]s Die-cast ML 7. aluminumAISI 316 ENCLOSU MF RE SS MATERIAL AISI 304 MC SS ¾" ET (F), 1 C0 No. ½" NPT (F), 1 C1 No. M20 x 1.5mm (F), 1 C2 No. ¾" NPT (F), 1 C3 8. CABLE No. ENTRY ¾" ET (F), 2 C5 Nos. ½" NPT (F), 2 C6 Nos. M20 x 1.5mm (F), 2 C8 Nos. ¾" NPT (F), 2 C9 Nos. ISO 9001 : 2015 www.miepl.co 02 MILLENNIUmM INSTRUMENTS LIMITED Tel : +91- 11- 220 143 25 / 27, Email : [email protected] MTR11 PROTECTION TUBE RTD ASSEMBLY ORDERING CODE MF - U5 - AC - A25 - MC AISI 304 M SS C AISI 316L M 9. PROTECTION TUBE SS GAISI 316 M MATERIAL SS F Tube Ø10 x 1.5 mm U THK 1 Tube Ø12 x 1.5 mm U THK 2 Pipe 3/8" Sch U 40 3 Pipe 3/8" Sch U 4 10. PROTECTION 80 TUBE Pipe ½" Sch U 40 5 Pipe ½" Sch U 80 6 Pipe ¾" Sch U 40 7 Pipe ¾" Sch U 80 8 Adjustable connection A 11. PROCESS CONNECTION C TYPE Fixed F connection C 1.5" RF 150# as per ANSI B A2 16.5 5 1.5" RF 300# as per ANSI B A2 16.5 6 1.5" RF 600# as per ANSI B A2 16.5 7 12. PROCESS 2" RF 150# as per ANSI B A3 CONNECTION 16.5 1 2" RF 300# as per ANSI B A3 16.5 2 2" RF 600# as per ANSI B A3 16.5 3 Oval T9 flange 9 13. PROCESS AISI 304 M CONNECTION MATERIAL SS CAISI 316 M 14. TOTAL LENGTH SS F (TL) 50 mm up to 5,000 XXXX 15. IMMERSION mm LENGTH (IL) 50 mm up to 5,000 XXXX 16. EXTENSION mm LENGTH 50 mm up to 250 XXX (XL) mm SC, Cable Gland, Ni-brass JB Terminal Head In SS JN WP 304 DC, Cable Gland, Ni-brass JC Terminal Head In SS JO WP 316 SC, Cable Gland,AISI 304 SS JD Terminal Head In Cast JP WP Iron DC, Cable Gland,AISI 304 SS JE SS base Plate For JQ WP Transmitter SC, Cable Gland,AISI 316 SS JF Head Mount JR WP Transmitter DC, Cable Gland,AISI 316 SS JG Plug Fitting For CE, JS 17. OTHER WP Aluminum OPTIONS SC, Cable Gland, Ni-brass JH Calibration JT FP Certificate DC, Cable Gland, Ni-brass JI Tag Plate, AISI 304 JU FP SS SC, Cable Gland,AISI 304 SS JJ SB FP DC, Cable Gland,AISI 304 SS JK WF FP SC, Cable Gland,AISI 316 SS JL FP JM DC, Cable Gland,AISI 316 SS FP Ordering Example MTR11 - PT100B - XXX - C - MF - M60 - BZ ML - CO - MF - U5 - AC - A25 - - MC 1. Other sheath diameters, materials and connections are available, please contact factory for details. 2. Not available in Double, 4-Wire combinations.. 3. WP = Weatherproof, FP = Flame proof, SC = Single Compression, DC = Double Compression, CE = Cable Entry, JB = Junction Box. 4. Transmitter output shall be 4…20 mA as standard, any other output required, please contact factory for details. ISO 9001 : 2015 www.miepl.co 03 MILLENNIUmM INSTRUMENTS LIMITED Tel : +91- 11- 220 143 25 / 27, Email : [email protected]