MIEPL Make MTT15 Protection Tube of Thermocouple have a ceramic material. This type of Thermocouple are used in high temperature & corrosive area. Get more information visit on:- www.miepl.com Our Mail I.D:- [email protected], [email protected], [email protected], [email protected] Contact us at:- +91-11-22014325, 22014327
MTT15 Protection Tube Thermocouple Assembly - Weldpad Mounting | Miepl
MTT15 PROTECTION TUBE THERMOCOUPLE ASSEMBLY
Weldpad Mounting
MIE P L M a k e M T T 1 5 P r o t e c t i o n
T u b e o f Thermocouple have a ceramic
material.
This type of Thermocouple are used in high
temperature & corrosive area.
STANDARD SPECIFICATIONS
Element : Type R (Pt-13%Rh/Pt)
FEATURES Element
: Element with ceramic
KER710 Material tAycpceuracy :in Ssutalandtoarrsd to ISA & ANSI
No. of MC96.1
Ceramic Insulator
Hseonts ors
:: SUinmgproleuxnded
Exchangeable insert jWunircet ion
Tdeiarmmeitne
:
arl head 24 AWG (0.511
Transmitter mountable : Screwed Type
Ttyepre
mm)
minal head ,Weatherproof, IP-65
Adjustable / Fixed ma
connection Cab
telrei al :: D¾i"e -EcTa s(tF A),l u1m inum
Henetardy extension :N Ho.ead with female
Single / Double protecting tSyuppeport tube
tube t: hArIeSaId 4in4g6
APPLICATION mPraoteterciatling tube S: SKER - 710, Recrystallised
Pmraoteterciatling tube size (OD :A l1u5m xina Reactors 10
PXr IoDc)ess connection m: Amdjustable
typ
Glass Pro
ecess :c o¾nn"e NcPtiTo n
Industries connection (M)
Oil & gas Process connection mat
: ASTM A 105 / Carbon
application
Steel
Sulfur recovery Overall length / Exposed lengtherial
: 500 mm / 300
plants :
Steel & Power mm Extension Length 100 mm
Industries
DRAWING Terminal
Head
Overall
Furnaces, Kilns & Length
Ovens Extensio Insertion
n Length
Length Exposed
Length
X7
ProtectionTub
e
Process Support
Connectio Tube X6
n
Cable
Entry
REFERENCE
IEC-584.2 / ANSI MC-
96.1
BX BZ BV BY BU BX BS BT
Single cable entry Dual cable entry
enclosures enclosures
ISO 9001 : 2015 www.miepl.co 01
m
MTT15 PROTECTION TUBE THERMOCOUPLE ASSEMBLY
ORDERING CODE MTT15 - k - X7 - P - V - U - MQ - M60 - A24 -
BZ
Type K (NiCr- K
Ni)
Type N (NiCrSi- N
NiSi)
1. ELEMENT Type R (Pt- R
13%Rh/Pt)
Type S (Pt- S
10%Rh/Pt)
Type B (Pt/30%Rh- B
Pt/6%Rh)
Mineral X6
2. ELEMENT TYPE insulated
Element with ceramic X7
insulator
Standard P
.3.
ACCURACY Special Q
Simplex V
4. NO. OF
SENSOR Triple X
S x
Duplex W
Ungrounded U
5. HOT JUNCTION
Grounded G
6.
SHEATH Inconel
MQ
MATERIAL 600
3.0 M30
mm
5.0 M50
mm
7. SHEATH 6.0 M60
DIAMETER mm
(For X6) 8.0 M80
mm
10.0 M10
mm
12.0 M12
mm
24 AWG (0.511 A24
mm)
8. SHEATH 25 AWG (0.455 A25
DIAMETER mm)
(For X7) 26 AWG (0.404 A26
mm)
27 AWG (0.361 A27
mm)
WP, IP 65, threaded BZ
cover
WP, IP 67, threaded BX
cover
Flame proof, IP 67, Gr IIA, BS
IIB
9. HEAD Explosion proof, IP 67, Gr BT
ENCLSUR IIC
E
WP, IP 65, Hinged BV
type
WP, IP 65, cover fitted with 2 BY
screws
Ex-Proof to CSA,FM,ATEX [EEx- BU
d]
ISO 9001 : 2015 www.miepl.co 02
MILLENNIUmM INSTRUMENTS LIMITED
Tel : +91- 11- 220 143 25 / 27, Email :
[email protected]
MTT15 PROTECTION TUBE THERMOCOUPLE ASSEMBLY
ORDERING CODE ML - CO - M6 -
P7
Die-cast ML
aluminum
10. ENCLOSURE AISI 304 MC
MATERIAL SS
AISI 316 MF
SS
¾" ET (F), 1 C0
No.
½" NPT (F), 1 C1
No.
M20 x 1.5mm (F), 1 C2
No.
¾" NPT (F), 1 C3
11. CABLE ENTRY No.
¾" ET (F), 2 C5
Nos.
½" NPT (F), 2 C6
Nos.
M20 x 1.5mm (F), 2 C8
Nos.
¾" NPT (F), 2 C9
Nos.
AISI 316 MF
SS
AISI 316L MG
12. SUPPORT SS
TUBE
MATERIAL AISI 310
ME
SS
Inconel MQ
600
AISI 446 M6
SS
13. INNER KER - 610, P6
PROTECTION Pythogoras
TUBE
MATERIAL KER - 710, Recrystallised P7
Alumina
Ø6 X 1.0 mm T06
thk
14. INNER Ø8 X 1.5 mm T08
PROTECTIO thk
N TUBE SIZE Ø10 X 2.0 mm T10
thk
Ø12 X 2.0 mm T12
thk
KER - 610, P6
Pythogoras
KER - 710, Recrystallised P7
Alumina
Kanthal P3
AF
Kanthal APM
15. OUTER P4
PROTECTION TUBE
MATERIA Inconel MQ
L 600
Silicon Sic
Carbide
Silicon Sin
Nitride
Cast Iron MM
(Barstock)
www.miepl.com 03
MILLENNIUM INSTRUMENTS LIMITED
Tel : +91- 11- 220 143 25 / 27, Email :
[email protected]
MTT15 PROTECTION TUBE THERMOCOUPLE ASSEMBLY
ORDERING CODE T50 - AC - 5NM -
MB
Ø6 X 1.0 mm T06
thk
Ø8 X 1.5 mm T08
thk
Ø10 X 2.0 mm T10
thk
16. OUTER
PROTECTIO Ø12 X 2.0 mm T12
N TUBE SIZE thk
Ø15 X 2.5 mm T50
thk
Ø20 X 2.5 mm T20
thk
Ø24 X 3.0 mm T24
thk
17. PROCESS Adjustable connection AC
CONNECTION
TYPE Fixed FC
connection
½" NPT 4NM
(M)
½" BSP 4BM
(M)
¾" NPT 5NM
(M)
¾" BSP 5BM
18. PROCESS
CONNECTION (M)
1" NPT 6NM
(M)
2" NPT 8NM
(M)
1" BSP 6BM
(M)
2" BSP 8BM
(M)
MB
19. PROCESS ASTM A 105 / Carbon
CONNECTION Steel
MATERIAL AISI 316 MF
SS
20. OVERALL /
EXPOSED 50 mm up to 2,000 XXXX/XXXX
mm
21. 50 mm up to 2,000 XXXX/XXXX
INSERTION /
EXPOSED mm
22. EXTENSION 50 mm up to 250 XXX
LENGTH (XL) mm
Calibration SB SC, cable gland, AISI 316 SS JH
Certificate WP
Tag plate, AISI 304 WF DC, cable gland, AISI 316 SS JI
SS WP
SC, cable gland, Ni-brass JD SC, cable gland, AISI 316 SS JN
WP FP
DC, cable gland, Ni-brass JE DC, cable gland, AISI 316 SS JO
WP FP
SC, cable gland, Ni-brass JJ Plug fitting for CE, AISI 304 JB
23. OTHER
OPTIONS FP SSDC, cable gland, Ni-brass JK Plug fitting for CE, AISI 316 JC
FP SS
SC, cable gland, AISI 304 SS JF Plug fitting for CE, JU
WP Aluminum
DC, cable gland, AISI 304 SS JG SS base plate for JS
WP transmitter
SC, cable gland, AISI 304 SS JL Head mount transmitter JT
FP
DC, cable gland, AISI 304 SS FP JM
P V U - MQ - M60- CO - M6 P7 T50 - AC
Ordering Example MTT15 - K - X7 - - A24 - BZ -
5NM MB
ML1 -. Other sheath diameters, connections are available, please contact factory for details..
2. WP = Weatherproof, FP = Flame proof, SC = Single Compression, DC = Double Compression, CE = Cable Entry
3. Transmitter output shall be 4…20 mA as standard, any other output required, please contact factory for details.