Uploaded on Nov 20, 2023
The benchtop multi-parameter water quality meter has many measurement modes for the quality and testing of water on various parameters. The pH, conductivity, and TDS concentration of the test sample are all measured. It can store and retrieve up to 500 data sets. Calibration due reminder alerts the operator to the need to calibrate the meter frequently.
Benchtop-Multi-parameter-Water-Quality-Meter
Benchtop Multi-parameter
Water Quality Meter
LMPWM-A40
www.labtron.com
[email protected]
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
Benchtop Multi-parameter Water Quality Meter LMPWM-A40 with 7 inch TFT display
measures pH, mV, relative mV, water hardness, and temperature and Ion concentration
of the sample. With expanded memory, it stores and recalls up to 1000 readings.
Calibration due reminder informs operator to calibrate the meter regularly.
Common features
- Auto read feature to lock and read endpoint measurement
- Stability indicator to record stable measurement reading
- Reset feature automatically sets all function to default condition
- Automatic interval readings, sends the measurement data to the
computer/printer
- USB communication interface to transfer store data
pH features
- 1-5 points push button calibration to automatically identify pH buffer
- Convenient to select pH buffer standard (USA/NIST/DIN) or custom calibration
solutions
- Automatic temperature compensation, provides accurate readings over entire
pH range
- Automatic electrode diagnosis with pH slope, offset display
- Alarm when pH readings are out of range
ORP features
- 1 point offset calibration, can adjust display value to known standard
- Relative and absolute millivolt mode of measurement
Water Hardness feature
- 2 to 5 points calibration with high to low concentration
- Advanced measurements using different measurement units
Ion features
- 2 to 5 points calibration, when 8 concentration points are selected
- Different concentration units like ppm, mg/l, mol/l, mmol/l for selection
- Automatic recognition of ion selective electrode
- Different Ion measurement methods for selection
- Calibration report with details of calibration standard and slope
Applications
Used in multi-parameters based research testing , and quality analysis of water, other
general liquids across water plants, food and beverages production units, laboratories,
and institutes.
Specication
Model no. LMPWM-A40
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18)
pH Buffer Solutions or DIN buffers
ORP Mode
mV Range ± 2000 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV, selectable
mV Calibration Points 1 Point, only for relative mode
Ion Mode
Ion measurement range
0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range
of ion selection )
Ion measurement
±0.5% F.S (Monovalent), ±1% F.S (Divalent)
accuracy
Ion measurement
0.001/0.01/0.1/1
resolution
Ion measurement
2 to 5 points
calibration points
Ion measurement 0.001/0.01/0.1/1/10/100/10 00/10000 ppm, mg/L,
calibration solutions mol/L
Ion measureme nt Direct re ading, Known addition, Known
methods subtraction, Sample addition, Sample subtraction
Water Hardness Mode
Water hardness 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000 °fH, 0-
measurement range 8000mg/L (Ca2+), 0~19999mg/L (CaCO3)
Water hardness
±1% F.S
measurement accuracy
Water hardness
0.001/0.01/0.1/1
measurement resolution
Water hardness
2 to 5 pointscalibration points
Water hardness
0.01/0.1/1/10/100 mmol/L
calibration solutions
Temperature Mode
Temperature
0 to 105°, 32 to 212 °F
measurement range
Temperature
± 0.5°C, ± 0.9°F
measurement accuracy
Temperature 0.1°C, 0.1°F
measurement resolution
Temperature
measurement 1 point
calibration points
Common Features
Temperature
0 to 100°C, 32 to 221°F
compensation range
Temperature
Manual or Automatic
compensation mode
Data hold Manual or Automatic end point detection
Stability criteria Standard or high accuracy
Calibration due alarm 1 to 31 days
Interval readings 10/30/60 seconds, 10/30 minutes or o ff
Password protection Ye s
Reset function Ye s
Memory Stores up to 1000 se ts dat a
Output USB communication interfac e
Connector BNC
Display 7 inch TFT LCD displa y
Power supply DC 12 V, AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H) 240 × 220 × 80 mm
Weight 1.7 kg
Standard Accessories
Accessorie s No. Name
1 pH electrode
2 Temperature probe
3 pH buffer pouches (4.01/7.0 0/10.01)
4 Ion selective electrode
5 Ion calibration standard solution 100 and 1000 ppm
6 Water hardness electrode
7 Water hardness calibratio n solutions
8 Electrode hold er
9 Power adapter
Optional Accessories
Accessories No. Name of the Ion electrode Range
1 NH4 [Ammonium] Electrode 5 × 10-6 ~1M
2 Br [Bromide] Electrode 5 × 10-6 ~1M
3 Ca [Calcium] Electrode
-7
5 × 10 ~1M
4 Cl [Chloride] Electrode
-6
5 × 10 ~1M
5 Cn [Cyanide] Electrode 5 × 10
-6 ~0.01M
6 F [Fluoride] Electrode 1 × 10-6 M~Saturatio n
7 NO -6 3 [Nitrate] Electrode 7 × 10 ~1M
8 Ag [Silver] Electrode 1 × 10-7 ~1M
9 Na [Sodium[ Electrode 1 × 10-5 ~1M
10 Cd [Cadmium] Electrode 1 × 10-6 ~0.1M
11 Cu [Cupric] Electrode 1 × 10-8 ~0.1M
12 I [Iodide] Electrode 5 × 10-8 ~1M
13 Pb [Lead[ Electrode 1 × 10-8 ~0.1M
14 K [Potassium] Electrode 1 × 10-6 ~1M
15 S [Sulphide] Electrode 1 × 10-7 ~1M
16 NH [Ammonia] Electrode 1 × 10-6 3 ~1M
Comments