Uploaded on Dec 12, 2023
Benchtop Water Hardness Meter has a large LCD display and used to test the hardness level of tap water, drinking water, filtered water & other industries.
Benchtop-Water-hardness-meter
BENCHTOP WATER
HARDNESS METER
LBWM-A10
www.labtron.com [email protected]
Benchtop Water hardness meter LBWM-A10
Benchtop Water hardness meter LBWM-A10 is equipped with large backlit LCD display, 2 to
5 points calibration with low to high concentration range. The calibration due reminder
alerts user for calibration of the meter on regular basis. The System menu allows setting the
7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other
elements at mg/L, mmol/ scale which causes hardness water.
Features
Large LCD display
Two to five points calibration with low to high range
System menu with 7 parameters setting
Stability indicator to robotically display current measurements
Automatic electrode diagnosis shows the slope of sensor
Calibration due reminder for regular calibration of the meter
Manual temperature compensation for better measurement accuracy of meter
Auto hold function freezes stable, final readings for better viewing and recording
Automatic temperature compensation for accurate measured value over the entire
range
Reset function
Enlarged memory can store up to 500 sets of data
Built-in real time clock stamps
Operational guide for Quick access to the conductivity meter
Applications
Benchtop water hardness meter is used in testing the hardness level of tap water, drinking
water, filtered water, water used for different experiments and testing across food, textile,
painting & other industries.
Specifications
Model no LBWM-A10
Water hardness range 0.05mmol/L-0.2mol/L
(CaCO3) 0-19999mg/L, (CaO) 0-11220mg/L,
(boiler) 0-400mmol/L, (Ca) 0-8020mg/L
(German degree) 0-11220dH, (English degree)
0-1404 0e, (French degree) 0-2000 0 f
Accuracy ±1%F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1mmol/L, 0.001, 0.01, 0.1mol/L
Temperature range 0 to 1050C
Temperature accuracy ±0.50C
Calibration range Measured value ±100C
Temperature compensation range 0-50 0C
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Power DC5V, using AC adapter, 220V/50Hz
Dimension (L*W*H) 210×180×60 mm
Weight 1.5 kg
Standard accessories
• Water hardness electrode
• Temperature probe
• Carrying case
Optional accessories
• Water hardness electrode range 0.00005 to 0.2M
Comments