Uploaded on Aug 9, 2020
Trumen vibrating fork point level switch model LFV suitable for all types of flow able liquids in all process industries. It gives reliable measurement and does not affected due to material flow, vibrations in the tank, changing the media properties and material build-up in the sensor. Trumen LFV available in three different design like ½”, ¾” and 1” depends upon the mounting requirements. #TrumenVibratingForkPointLevelSwitchSupplierinIndia #TrumenVibratingForkPointLevelSwitchManufacturerinIndia #TrumenVibratingForkPointLevelSwitchExporterinIndia
Trumen Vibrating Fork Point Level Switch Supplier Manufacturer Exporter in India
ABOU FEATURE APPLICATIO OPERATIO TECHNICA CONTA
T S N N L CT
ABOUT LFV ABOUT TRUMEN
Trumen vibrating fork point level switch Trumen came into existence in 2009 and
model LFV suitable for all types of flow initially started with manufacturing of
able liquids in all process industries. It Tuning Fork Level Switches for liquid and
gives reliable measurement and does not solid applications. With time, the
affected due to material flow, vibrations in manufacturing range increased with
the tank, changing the media properties and addition of Capacitance Level Transmitter &
material build-up in the sensor. Capacitance Level Switches, RF Admittance
Level Switches, Rotating Paddle Level
Trumen LFV available in three different Switches, Conductivity Type Level
design like ½”, ¾” and 1” depends upon Switches, Vibrating Rod Level Switches,
the mounting requirements. Hydrostatic Level Transmitter, Radar.
KNOW MORE KNOW MORE
FEATURES
Compact Size.
Calibration-less
operation.
Universal power supply on same terminals (15 to 80VDC or 15 to
260VAC). Inbuilt settable switching delay 5 sec.
Tropicalized sealed electronics module & easy to maintenance.
Customized process connection threaded / flanged / hygienic & dairy fittings
etc. Various output options like transistor PNP/NPN , NAMUR, 8/16mA current
output. Etc.
APPROVALS
CE
Certification.
IP-68/ 66.
Exd Suitable for gas group IIC, T6 as per IEC 60079-1:2007 & IEC
60529:2001. Ex ia suitable for gas group IIC T6, as per, IS/IEC 60079-
11:2006.
Vibration test comply as per IEC standard 60068-Part 2-6.
Functionality and environmental test of all instruments RFI-EMC, voltage
transient and electrical functionality test as per IEC 61000.
APPROVALS
Trumen vibrating fork point level switch model LFV is used in different
applications like -
ITrumen vibrating fork is used in different applications like, Water, oil, milk,
chemicals, solvents and liquids having viscosity up-to 10,000Cp.
Suitable for hazardous liquids & chemicals.
Process temperature maximum 200° C / 250° C (available on
requirement). Operating pressure 20 bar maximum.
OPERATING PRINCIPLE
Electronics of LFV When fork tines are This change in
excites the piezoelectric immersed in liquid, the frequency is detected by
crystals inside the frequency of fork the electronic circuit.
tuning fork which makes vibration falls due to
the fork tines vibrate at the density of liquid.
their natural resonance
frequency in free air.
OPERATION
Device operation and settings:
Trumen LFV is very easy to
1operatOepen the cover of Trumen LFV you can see there are 9 terminals.
. Terminal 1, 2 & 3 are for auxiliary power supply. Terminal 4, 5, 6 & 7,
8, 9 are for relay output.
2 Connect the power supply either 15 to 80VDC or 15 to 260VAC on
. terminal 1 & 2 and plant earth on terminal number 3. Now switch on the
3 power. Trumen LFV starts vibrating in air. Power LED is on and status level
. is in OFF condition.
4 Now fill the liquid up-to the fork tines level.
. You can see the status LED of LFV is on means liquid reaches to the desired
5 level. Now empty the liquid, you can see the status LED is OFF means
. material goes below the desired level.
76. Relay status also change from NC to NO.
8. There are 4 DIP switches provided on connection panel. Via DIP switch no.1 we can set
. the sensitivity that means if the density of liquid is low density fluids we need to on
switch no.1 in this conditon LFV will sense the liquid. Keep it turned off for normal
9 density fluids. Switch no.2 is to set dry delay means off delay. ON the DIP switch
. no.2 and empty the material. LFV will wait for 5 sec once the material goes below the
sensor and after 5 sec it generates switching. During the delay cycle sensor ignore
10 the turbulence.
. Switch no.3 is to set wet delay means on delay. ON the DIP switch no.3 and fill
the material. LFV will wait for 5 sec once the material touches the sensor and
11 after 5 sec it generates switching. During the delay cycle sensor ignore the
. turbulence.
Switch no.4 is to set failsafe means the instrument should be in alarm condition if
the sensor faces power failure. When the sensor is installed for high level keep the
12 DIP switch no.4 is turned off i.e failsafe high or maximum and when the sensor is
. installed for low level keep the DIP switch no.4 turn on i.e. failsafe low or
13 minimum.
. You can easily replace the electronics as shown
In case of any further technical support please contact our sales and support team.
Connection Terminals
+ of DC or Live of AC Supply input
- of DC or Neutral of AC Supply input
Supply: 15 to 80VDC or 15 to 260VAC
50/60Hz
Earth terminal for safety
Normally connected terminal of contact
1 Common terminal of contact 1
Normally open terminal of contact 1
Normally connected terminal of contact
2 Common terminal of contact 2
Normally open terminal of contact 2
TYPICAL MOUNTING TYPICAL MOUNTING
TECHNICAL DATA & INSTRUCTION MANUAL
TESTIMONIALS
WHAT OUR
HAPPY CLIENTS
SAYS ABOUT
US
TRUMEN LFV USERS
TRUMEN EXPORT TO
Quick Links
ABOUT LFV FEATURES APPLICATION OPERATING OPERATION TECHNICAL DATA & TRUMENT AT
A
PRINCIPLE INSTRUCTION MANUAL GLANCE
39, Mangal Nagar, Behind Sai Ram Plaza, 0731-4972065, +91-7049333121, suppor